| AN.AFD.02 |  | Application Note Ethernet CM090 to AB PLC5 Multiple files exist. Please view the details | Application Note | 08/13/2004 | 21 KB, 375 KB |
| AN.AFD.03 |  | Application Note Ethernet CM090 to AB SLC PLC Multiple files exist. Please view the details | Application Note | 08/13/2004 | 379 KB, 9 KB |
| DD.AFD.096.01 |  | Dimension Drawing for Enclosure, NEMA 1/12, Floor Mount, Double Door, External Heatsink, 73 Wide Multiple files exist. Please view the details | Dimension/Outline Diagram | 04/26/2004 | 126 KB, 88 KB, 1.8 MB |
| DD.AFD.129.01 |  | Dimension Drawing for Enclosure W1, NEMA Type 1/12 or IP54, 26H x 17.5W x 12D Multiple files exist. Please view the details | Dimension/Outline Diagram | 04/26/2005 | 99 KB, 770 KB, 299 KB |
| DD.AFD.130.01 |  | Dimension Drawing for Enclosure W2, NEMA Type 1/12 or IP54, 32H X 20W X 16D Multiple files exist. Please view the details | Dimension/Outline Diagram | 04/26/2005 | 95 KB, 783 KB, 299 KB |
| DD.AFD.131.01 |  | Dimension Drawing for Enclosure W3, NEMA Type 1/12 or IP54, 37H X 25W X 16D Multiple files exist. Please view the details | Dimension/Outline Diagram | 04/26/2005 | 94 KB, 299 KB, 780 KB |
| DD.AFD.132.01 |  | Dimension Drawing for Enclosure W4, NEMA Type 1/12 or IP54, 48H X 28W X 20D Multiple files exist. Please view the details | Dimension/Outline Diagram | 04/26/2005 | 97 KB, 806 KB, 333 KB |
| DD.AFD.189.01 |  | Dimensions Enclosure, NEMA 3R, Floor Mount, Single Door Multiple files exist. Please view the details | Dimension/Outline Diagram | 09/26/2007 | 356 KB, 168 KB |
| DD.AFD.190.01 |  | Dimensions Enclosure, NEMA 3R, Floor Mount, Double Door Multiple files exist. Please view the details | Dimension/Outline Diagram | 09/27/2007 | 401 KB, 155 KB |
| DD.AFD.198.01 |  | Dimensions Enclosure, NEMA 3R, Wall Mount, Single Door Multiple files exist. Please view the details | Dimension/Outline Diagram | 10/28/2009 | 520 KB, 298 KB, 557 KB |
| DD.AFD.199.01 |  | Dimensions Enclosure, NEMA 3R, Wall Mount, Single Door Multiple files exist. Please view the details | Dimension/Outline Diagram | 10/29/2009 | 215 KB, 332 KB, 778 KB |
| DD.AFD.200.01 |  | Leg Stand Mounting Option Dimensions Multiple files exist. Please view the details | Dimension/Outline Diagram | 09/16/2009 | 722 KB, 1.2 MB |
| DD.F7.FR10.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 10 IP00 (for CIMR-F7U2055 to 2075, 4075 to 4090) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/13/2003 | 222 KB, 1.2 MB |
| DD.F7.FR10.N1.01 |  | Dimension Drawing for F7 drive Frame Size 10 NEMA Type 1/IP20 (for CIMR-F7U2055, 2075, 4075 and 4090) Multiple files exist. Please view the details | Dimension/Outline Diagram | 07/15/2003 | 282 KB, 1.1 MB |
| DD.F7.FR11.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 11 IP00 (for CIMR-F7U2090, 4110 to 4132) Multiple files exist. Please view the details | Dimension/Outline Diagram | 07/07/2003 | 254 KB, 2.7 MB |
| DD.F7.FR11.N1.01 |  | Dimension Drawing for F7 drive Frame Size 11 NEMA Type 1/IP20 for CIMR-F7U2090, 4110 and 4132 Multiple files exist. Please view the details | Dimension/Outline Diagram | 07/07/2003 | 236 KB, 2.7 MB |
| DD.F7.FR12.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 12 IP00 (for CIMR-F7U2110) Multiple files exist. Please view the details | Dimension/Outline Diagram | 09/16/2003 | 238 KB, 2.8 MB |
| DD.F7.FR13.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 13 IP00 for CIMR-F7U4160 Multiple files exist. Please view the details | Dimension/Outline Diagram | 07/07/2003 | 239 KB, 2.9 MB |
| DD.F7.FR13.N1.01 |  | Dimension Drawing for F7 drive Frame Size 13 NEMA Type 1/IP20 for CIMR-F7U4160 Multiple files exist. Please view the details | Dimension/Outline Diagram | 07/07/2003 | 231 KB, 3.0 MB |
| DD.F7.FR14.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 14 IP00 (for CIMR-F7U4185 and 4220) Multiple files exist. Please view the details | Dimension/Outline Diagram | 09/16/2003 | 235 KB, 2.8 MB |
| DD.F7.FR14.N1.01 |  | Dimension Drawing for F7 drive Frame Size 14 NEMA Type 1/IP20 for CIMR-F7U4185 and 4220 Multiple files exist. Please view the details | Dimension/Outline Diagram | 08/08/2008 | 221 KB, 1.2 MB, 5.4 MB |
| DD.F7.FR15.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 15 IP00 (for CIMR-F7U4300) Multiple files exist. Please view the details | Dimension/Outline Diagram | 09/16/2003 | 310 KB, 3.9 MB |
| DD.F7.FR15.N1.01 |  | Dimension Drawing for F7 drive Frame Size 15 NEMA Type 1/IP20 for CIMR-F7U4300 Multiple files exist. Please view the details | Dimension/Outline Diagram | 08/08/2008 | 308 KB, 2.0 MB, 8.6 MB |
| DD.F7.FR1.N1.01 |  | Dimension Drawing for F7 drive Frame Size 1 NEMA Type 1/IP20 and IP00 for CIMR-F7U20P4 to 22P2 and 40P4 to 41P5 Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/13/2003 | 109 KB, 599 KB |
| DD.F7.FR2.N1.01 |  | Dimension Drawing for F7 drive Frame Size 2 NEMA Type 1/IP20 and IP00 (for CIMR-F7U23P7 to 25P5, 42P2 to 45P5) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/13/2003 | 132 KB, 658 KB |
| DD.F7.FR3A.N1.01 |  | Dimension Drawing for F7 drive Frame Size 3A NEMA Type 1/IP20 and IP00 (for CIMR-F7U27P5, 47P5 to 4011) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/13/2004 | 151 KB, 871 KB |
| DD.F7.FR3B.N1.01 |  | Dimension Drawing for F7 drive Frame Size 3B NEMA Type 1/IP20 and IP00 (for CIMR-F7U2011) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/13/2003 | 150 KB, 847 KB |
| DD.F7.FR4A.N1.01 |  | Dimension Drawing for F7 drive Frame Size 4A NEMA Type 1/IP20 and IP00 (for CIMR-F7U2015, 4018) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/28/2003 | 124 KB, 689 KB |
| DD.F7.FR4B.N1.01 |  | Dimension Drawing for F7 drive Frame Size 4B NEMA Type 1/IP20 and IP00 (for CIMR-F7U4015) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/28/2003 | 124 KB, 688 KB |
| DD.F7.FR4C.N1.01 |  | Dimension Drawing for F7 drive Frame Size 4C NEMA Type 1/IP20 and IP00 (for CIMR-F7U2018) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/28/2003 | 125 KB, 711 KB |
| DD.F7.FR5.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 5 IP00 (for CIMR-F7U2022) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/28/2003 | 117 KB, 629 KB |
| DD.F7.FR5.N1.01 |  | Dimension Drawing for F7 drive Frame Size 5 NEMA Type 1/IP20 (for CIMR-F7U2022) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/28/2003 | 107 KB, 538 KB |
| DD.F7.FR6A.N1.01 |  | Dimension Drawing for F7 drive Frame Size 6A NEMA Type 1/IP20 (for CIMR-F7U2030) Multiple files exist. Please view the details | Dimension/Outline Diagram | 05/28/2003 | 135 KB, 680 KB |
| DD.F7.FR6B.N1.01 |  | Dimension Drawing for F7 drive Frame Size 6B NEMA Type 1/IP20 for CIMR-F7U4022 and 4030 Multiple files exist. Please view the details | Dimension/Outline Diagram | 06/16/2003 | 123 KB, 618 KB |
| DD.F7.FR6.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 6 IP00 for CIMR-F7U2030 4022 and 4030 Multiple files exist. Please view the details | Dimension/Outline Diagram | 06/16/2003 | 137 KB, 703 KB |
| DD.F7.FR7.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 7 IP00 for CIMR-F7U2037 Multiple files exist. Please view the details | Dimension/Outline Diagram | 06/16/2003 | 188 KB, 1.1 MB |
| DD.F7.FR7.N1.01 |  | Dimension Drawing for F7 drive Frame Size 7 NEMA Type 1/IP20 for CIMR-F7U2037 Multiple files exist. Please view the details | Dimension/Outline Diagram | 06/16/2003 | 166 KB, 902 KB |
| DD.F7.FR8.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 8 IP00 for CIMR-F7U2045 Multiple files exist. Please view the details | Dimension/Outline Diagram | 06/16/2003 | 189 KB, 1.1 MB |
| DD.F7.FR8.N1.01 |  | Dimension Drawing for F7 drive Frame Size 8 NEMA Type 1/IP20 for CIMR-F7U2045 Multiple files exist. Please view the details | Dimension/Outline Diagram | 06/16/2003 | 169 KB, 912 KB |
| DD.F7.FR9A.N1.01 |  | Dimension Drawing for F7 drive Frame Size 9A NEMA Type 1/IP20 (for CIMR-F7U4037) Multiple files exist. Please view the details | Dimension/Outline Diagram | 07/15/2003 | 221 KB, 715 KB |
| DD.F7.FR9B.N1.01 |  | Dimension Drawing for F7 drive Frame Size 9B NEMA Type 1/IP20 (for CIMR-F7U4045 and 4055) Multiple files exist. Please view the details | Dimension/Outline Diagram | 07/15/2003 | 214 KB, 662 KB |
| DD.F7.FR9.IP00.01 |  | Dimension Drawing for F7 drive Frame Size 9 IP00 (for CIMR-F7U4037 to 4055) Multiple files exist. Please view the details | Dimension/Outline Diagram | 07/15/2003 | 230 KB, 799 KB |
| DO.F7C.01 |  | Operator Drawing F7C Drive Multiple files exist. Please view the details | Dimension/Outline Diagram | 08/24/2004 | 85 KB, 156 KB, 430 KB |
| DS.F7.01 |  | Schematic Diagram of F7 drive Multiple files exist. Please view the details | Schematic Wiring Diagram | 02/10/2005 | 142 KB, 260 KB, 602 KB |
| F7C-00 |  | Schematic Diagram of F7 Configured drive Multiple files exist. Please view the details | Schematic Wiring Diagram | 01/22/2004 | 354 KB, 519 KB, 200 KB, 667 KB |
| F7C-10 |  | Schematic Diagram for F7C with dynamic braking option PJ Multiple files exist. Please view the details | Schematic Wiring Diagram | 01/22/2004 | 262 KB, 526 KB, 197 KB, 563 KB |
| UDM00120 |  | Dimension for Remote Mounted Digital Operator Cutout for F7, G7, P7, E7 drives Multiple files exist. Please view the details | Dimension/Outline Diagram | 08/14/2009 | 174 Bytes, 287 KB, 90 KB |
| UDM00201 |  | Digital Operator Cutout Template Multiple files exist. Please view the details | Artwork/Label/Drilling Diagram | 03/03/2007 | 171 Bytes, 115 KB, 92 KB |
| TM.F7.01 |  | User Manual for F7 Drive | Technical Manuals | 08/01/2008 | 6.0 MB |
| TM.F7.02 |  | Programming Manual for F7 Drive | Technical Manuals | 04/01/2006 | 2.6 MB |
| IG.AFD.25 |  | Installation Guide for Modbus TCP/IP Option Card CM090 | Installation Guides | 10/07/2009 | 2.4 MB |
| IG.EZZ006543 |  | Installation Guide for Making Yaskawa Drives Conform with the EMC Directive | Installation Guides | 04/04/2002 | 353 KB |
| TM.F7SW.056 |  | F7 Drive Software Technical Manual 1500 Hz Output Frequency | Technical Manuals | 05/05/2005 | 1.0 MB |
| IG.AFD.13 |  | Installation Guide for DeviceNet Option Card CM059 | Installation Guides | 09/30/2009 | 1.5 MB |
| IG.AFD.14 |  | Installation Guide for DeviceNet Option Card CM05X | Installation Guides | 07/01/2004 | 113 KB |
| IG.F7C.01 |  | Installation Guide for Heatsink Filter Kit Option for F7 Configured Drive | Installation Guides | 03/05/2004 | 245 KB |
| TM.AFD.13 |  | Technical Manual for DeviceNet Option Card CM059 | Technical Manuals | 09/30/2009 | 2.4 MB |
| TM.AFD.14 |  | Technical Manual for DeviceNet Option Card CM05x | Technical Manuals | 12/01/2005 | 726 KB |
| UDA00417 |  | Installation Guide and Diagram. E7 F7 G7 P7 iQpump Ring Kit Attachment | Installation Guides | 05/01/2005 | 1.8 MB |
| AN.AFD.07 |  | Application Note Ethernet CM090 to Modicon PLC | Application Note | 05/27/2005 | 93 KB |
| TM.F7.11 |  | Technical Manual for F7 Modbus | Technical Manuals | 11/30/2005 | 4.4 MB |
| IG.AFD.60 |  | Installation Guide for Encoder Feedback Option Card PG-X2 | Installation Guides | 07/01/2004 | 114 KB |
| IG.AFD.61 |  | Installation Guide for Dual Encoder Feedback Option Card PG-W2 | Installation Guides | 07/01/2004 | 101 KB |
| IG.AFD.63 |  | Installation Guide for 120 VAC Interface Option Card DI-001 | Installation Guides | 10/27/2005 | 60 KB |
| IG.AFD.57 |  | Installation Guide for Digital Output Option Card DO-02C | Installation Guides | 07/01/2004 | 113 KB |
| IG.AFD.59 |  | Installation Guide for Digital Input Option Card DI-16H2 | Installation Guides | 07/01/2004 | 68 KB |
| IG.AFD.62 |  | Installation Guide for Analog Input Trim Potentiometer Option Card AI-001 | Installation Guides | 07/01/2004 | 35 KB |
| IG.AFD.51 |  | Installation Guide for Analog Ouput Option Card AO-08 AO-12 | Installation Guides | 07/01/2004 | 63 KB |
| IG.AFD.53 |  | Installation Guide for Analog Input Option Card AI-14U | Installation Guides | 07/01/2004 | 44 KB |
| IG.AFD.54 |  | Installation Guide for Analog Input Option Card AI-14B | Installation Guides | 07/01/2004 | 81 KB |
| IG.AFD.56 |  | Installation Guide for Digital Output Option Card DO-08 | Installation Guides | 07/01/2004 | 108 KB |
| IG.AFD.58 |  | Installation Guide for Digital Input Option Card DI-08 | Installation Guides | 07/01/2004 | 49 KB |
| IG.AFD.52 |  | Installation Guide for Isolated Analog Output Option Card AO-001 | Installation Guides | 11/03/2004 | 89 KB |
| IG.AFD.55 |  | Installation Guide for Isolated Analog Input Option Kit AI-040 | Installation Guides | 10/07/2005 | 230 KB |
| AN.AFD.04 |  | Application Note Power Line Harmonics and Installation Considerations for AC Drives | Application Note | 10/10/2004 | 203 KB |
| IG.AFD.26 |  | Installation Guide for EtherNet/IP Option Kit CM092 | Installation Guides | 08/18/2011 | 7.8 MB |
| TM.AFD.26 |  | EtherNet/IP Option CM092 Technical Manual | Technical Manuals | 04/13/2010 | 8.9 MB |
| WP.AFD.02 |  | White Paper on Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation | White Paper | 12/01/2005 | 104 KB |
| AN.AFD.09 |  | Application Note: EtherNet/IP CM092/CM093 Option with AB Controllogix / Compactlogix Programmable Controllers | Application Note | 03/15/2007 | 243 KB |
| TOCP-C710616-09A |  | F7 Instruction Manual | Technical Manuals | 03/01/2005 | 18.3 MB |
| WP.AFD.04 |  | High Slip Braking (HSB) Software | White Paper | 04/01/2009 | 133 KB |
| TOBPC72060000 |  | YASKAWA AC Drive-Option Instructions, BRAKING UNIT- CDBR, BRAKING RESISTOR UNIT-LKEB | Installation Guides | 03/31/2010 | 1.2 MB |
| TOBPC72060001 |  | YASKAWA AC Drive-Option Instructions, BRAKING UNIT- CDBR Spec. D, BRAKING RESISTOR UNIT-LKEB | Installation Guides | 03/31/2012 | 4.8 MB |
| AN.AFD.27 |  | Protective Enclosures for Yaskawa AC Drives | Application Note | 04/01/2012 | 212 KB |
| AN.AFD.28 |  | Using PTC Thermistors with Yaskawa AC Drives | Application Note | 04/01/2012 | 315 KB |
| EZZ020801 |  | F7 to A1000 Replacement Attachment Mounting Dimensions and Procedure | Dimension/Outline Diagram | 09/01/2012 | 2.2 MB |
| IG.AFD.12 |  | Installation Guide for Profibus DP Option Card CM061 | Installation Guides | 11/17/2006 | 1.9 MB |
| IG.AFD.20 |  | Installation Guide for LonWorks Option Card CM048 | Installation Guides | 03/02/2012 | 600 KB |
| IG.AFD.50 |  | Installation Guide for Pressure Transducer 3-15 PSI Analog Input Option Card AI-010 | Installation Guides | 05/22/2007 | 407 KB |
| TM.AFD.12 |  | Technical Manual for Profibus-DP Option Card CM061 | Technical Manuals | 01/31/2004 | 2.4 MB |
| TOBPC73060010 |  | PG Speed Control Card PG-X2
G5/F7/G7 Option Card Instructions | Technical Manuals | 06/01/2010 | 907 KB |
| YEA-TOE-S616-55.1D |  | F7A Drive Instruction Manual for Asia Spec. A drives | Technical Manuals | 12/01/2007 | 10.1 MB |
| TM.F7.03 |  | F7 Drive Safe-Off Option Technical Manual | Technical Manuals | 10/15/2007 | 651 KB |
| IG.AFD.16 |  | DeviceNet with ADR Option Kit CM012 Installation Guide | Installation Guides | 06/15/2007 | 282 KB |
| TM.AFD.16 |  | CM012 DeviceNet Option Card Technical Manual | Technical Manuals | 09/01/2007 | 3.4 MB |
| AN.AFD.14 |  | Comparison of Yaskawa DeviceNet Solutions | Application Note | 02/26/2008 | 55 KB |
| AN.AFD.15 |  | Applying Drives to Single-Phase Input Applications | Application Note | 07/25/2008 | 542 KB |
| AN.AFD.16 |  | Adding Drive I/O Tags to RSLogix 5000 with Yaskawa`s Tag Generation Utility | Application Note | 10/23/2011 | 1.7 MB |
| AN.AFD.17 |  | Motor Bearing Current Phenomenon | Application Note | 08/07/2008 | 159 KB |
| AN.AFD.19 |  | Replacing a 7 Series Drive with a 1000 Series Drive for PROFIBUS Communication | Application Note | 04/02/2009 | 2.2 MB |
| TM.DW.04 |  | User`s Manual - DriveWizard AC Drive Support Software | Technical Manuals | 04/28/2006 | 2.8 MB |
| AN.AFD.20 |  | Procedure for Inverter Storage | Application Note | 11/30/2009 | 359 KB |
| TM.AFD.20 |  | Technical Manual for LonWorks Option Card CM048 | Technical Manuals | 09/01/2006 | 2.4 MB |
| TM.F7SW.064 |  | Electronic Lineshaft with Alignment F7 Drive Software Technical Manual | Technical Manuals | 02/24/2010 | 1.3 MB |
| IG.AFD.17 |  | Installation Guide for Modbus Plus Option Card CM071 | Installation Guides | 11/17/2006 | 545 KB |
| TM.F7SW.063 |  | F7 Drive Software Technical Manual Orientation | Technical Manuals | 03/03/2006 | 744 KB |
| TM.F7SW.058 |  | F7 Drive Software Technical Manual Enhanced PID With Digital Velocity Follower | Technical Manuals | 06/11/2007 | 814 KB |
| TM.F7SW.061 |  | F7 Drive Software Technical Manual Output Voltage PID | Technical Manuals | 07/15/2008 | 1.1 MB |
| TM.F7SW.062 |  | F7 Drive Software Technical Manual Overvoltage Suppression | Technical Manuals | 09/17/2010 | 513 KB |
| TM.F7SW.096 |  | F7 Drive Software Technical Manual Enhanced PID for Air Compressor | Technical Manuals | 08/01/2005 | 840 KB |
| AN.AFD.10 |  | Application Note: Commissioning the CM092/CM093 EtherNet/IP Option Kit with the Rockwell BOOTP/DHCP Server. | Application Note | 08/06/2009 | 785 KB |
| IG.AFD.72 |  | Installation Guide for Digital Operator Remote Mounting Kits UUX000458 and UUX000459 with UL Type 1, 3R, 4, 4X, and 12 Rating. | Installation Guides | 06/14/2007 | 133 KB |
| WD.DW.05 |  | Wiring Diagram for DriveWizard and DriveWizard Plus Cable to Drive | Schematic Wiring Diagram | 05/23/2011 | 30 KB |
| TM.DW.04 |  | User Manual for DriveWizard 6.1 Software | Technical Manuals | 04/01/2006 | 2.8 MB |
| AN.AFD.21 |  | Communication Loss Detection Feature of Yaskawa Ethernet Modbus/TCP Options | Application Note | 08/09/2010 | 908 KB |