Line/Load Reactors, 3% and 5% Impedance for P1000 Drive

200-240V, 3% Reactors | 200-240V, 5% Reactors | 240V, 1-Phase
380-480V, 3% Reactors | 380-480V, 5% Reactors | 480V, 1-Phase
500-600V, 3% Reactors | 500-600V, 5% Reactors | 600V, 1-Phase

200-240V, 3% Line/Load Reactors
Rated Input Voltage
Nominal HP
Drive Model Number
Nominal 3% Impedance
Reactor Rated Current (A)
Inductance (μH)
Enclosed Part Number
Weight (lb)
200-240V, 3-Phase
1/2
CIMR-PU2A0004
2
6000
URX000243
10
3/4
CIMR-PU2A0004
4
3000
05P00620-0020
11
200-240V, 3-Phase
1
CIMR-PU2A0006
4
3000
05P00620-0020
11
1.5
CIMR-PU2A0006
8
1500
05P00620-0027
14
200-240V, 3-Phase
2
CIMR-PU2A0008
8
1500
05P00620-0027
14
3
CIMR-PU2A0010
12
1250
05P00620-0032
16
200-240V, 3-Phase
5
CIMR-PU2A0018
18
800
05P00620-0036
16
7.5
CIMR-PU2A0021
25
500
05P00620-0041
29
200-240V, 3-Phase
10
CIMR-PU2A0030
35
400
05P00620-0046
32
15
CIMR-PU2A0040
45
300
05P00620-0050
41
200-240V, 3-Phase
20
CIMR-PU2A0056
55
250
05P00620-0054
42
25
CIMR-PU2A0069
80
200
05P00620-0058
43
200-240V, 3-Phase
30
CIMR-PU2A0081
80
200
05P00620-0058
43
200-240V, 3-Phase
40
CIMR-PU2A01101
100
150
URX000204
47
50
CIMR-PU2A01381
130
150
05P00620-0066
47
200-240V, 3-Phase
60
CIMR-PU2A01691
160
75
URX000206
59
75
CIMR-PU2A02111
250
45
URX000248
65
200-240V, 3-Phase
100
CIMR-PU2A02501
250
45
URX000248
65
125
CIMR-PU2A03121
320
40
URX000249
107
200-240V, 3-Phase
150
CIMR-PU2A03601
400
30
URX000250
111
175
CIMR-PU2A04151
500
25
URX000251
111
1"Large" P1000 chassis have a built-in DC link reactor equivalent to 3% line reactance. 240 VAC ratings are shown with 3% added AC reactance for 6% total.

Top

200-240V, 5% Line/Load Reactors
Rated Input Voltage
Nominal HP
Drive Model Number
Nominal 5% Impedance
Reactor Rated Current (A)
Inductance (μH)
Enclosed Part Number
Weight (lb)
200-240V, 3-Phase
1/2
CIMR-PU2A0004
2
12000
05P00620-0015
11
3/4
CIMR-PU2A0004
4
6500
05P00620-0021
11
200-240V, 3-Phase
1
CIMR-PU2A0006
4
6500
05P00620-0021
11
1.5
CIMR-PU2A0006
8
3000
05P00620-0028
15
200-240V, 3-Phase
2
CIMR-PU2A0008
8
3000
05P00620-0028
15
3
CIMR-PU2A0010
12
2500
05P00620-0033
17
200-240V, 3-Phase
5
CIMR-PU2A0018
18
1500
05P00620-0037
15
7.5
CIMR-PU2A0021
25
1200
05P00620-0042
32
200-240V, 3-Phase
10
CIMR-PU2A0030
35
800
05P00620-0047
34
15
CIMR-PU2A0040
45
700
05P00620-0051
46
200-240V, 3-Phase
20
CIMR-PU2A0056
55
500
05P00620-0055
45
25
CIMR-PU2A0069
80
400
05P00620-0059
51
200-240V, 3-Phase
30
CIMR-PU2A0081
80
400
05P00620-0059
51
200-240V, 3-Phase
40
CIMR-PU2A01101
100
150
URX000204
47
50
CIMR-PU2A01381
130
100
05P00620-0066
47
200-240V, 3-Phase
60
CIMR-PU2A01691
160
75
URX000206
59
75
CIMR-PU2A02111
250
45
URX000248
65
200-240V, 3-Phase
100
CIMR-PU2A02501
250
45
URX000248
65
125
CIMR-PU2A03121
320
40
URX000249
107
200-240V, 3-Phase
150
CIMR-PU2A03601
400
30
URX000250
111
175
CIMR-PU2A04151
500
25
URX000251
111
1"Large" P1000 chassis have a built-in DC link reactor equivalent to 3% line reactance. 240 VAC ratings are shown with 3% added AC reactance for 6% total.

Top

240V, Single-Phase Line/Load Reactors
Rated Input Voltage
Nominal HP
Drive Model Number
Enclosed AC Reactor
Current (A)
Inductance (μH)
Part Number
240V, 1-Phase
1/2
CIMR-PU2A0004
6
1.500
URX000411
3/4
CIMR-PU2A0006
6
1.500
URX000411
240V, 1-Phase
1
CIMR-PU2A0008
11
1.000
URX000413
1
CIMR-PU2A0010
14
0.790
URX000415
240V, 1-Phase
2
CIMR-PU2A0012
21
0.530
URX000418
3
CIMR-PU2A0018
28
0.390
URX000420
240V, 1-Phase
3
CIMR-PU2A0021
35
0.350
URX000422
3
CIMR-PU2A0030
35
0.350
URX000422
240V, 1-Phase
5
CIMR-PU2A0040
35
0.350
URX000422
7.5
CIMR-PU2A0056
46
0.300
URX000424
240V, 1-Phase
10
CIMR-PU2A0069
65
0.190
URX000426
15
CIMR-PU2A0081
104
0.120
URX000428

Top

380-480V, 3% Line/Load Reactors
Rated Input Voltage
Nominal HP
Drive Model Number
Nominal 3% Impedance
Reactor Rated Current (A)
Inductance (μH)
Enclosed Part Number
Weight (lb)
380-480V, 3-Phase
1/2
CIMR-PU4A0002
1
18000
URX000242
11
3/4
CIMR-PU4A0002
2
12000
05P00620-0015
11
380-480V, 3-Phase
1
CIMR-PU4A0002
2
12000
05P00620-0015
11
1.5
CIMR-PU4A0004
4
6500
05P00620-0021
11
380-480V, 3-Phase
2
CIMR-PU4A0004
4
6500
05P00620-0021
11
3
CIMR-PU4A0005
8
3000
05P00620-0028
15
380-480V, 3-Phase
5
CIMR-PU4A0009
8
3000
05P00620-0028
15
7.5
CIMR-PU4A0011
12
2500
05P00620-0033
17
380-480V, 3-Phase
10
CIMR-PU4A0018
18
1500
05P00620-0037
19
15
CIMR-PU4A0023
25
1200
05P00620-0042
32
380-480V, 3-Phase
20
CIMR-PU4A0031
35
800
05P00620-0047
34
25
CIMR-PU4A0038
35
800
05P00620-0047
34
380-480V, 3-Phase
30
CIMR-PU4A0044
45
700
05P00620-0051
46
380-480V, 3-Phase
40
CIMR-PU4A00581
55
250
05P00620-0054
42
50
CIMR-PU4A00721
80
200
05P00620-0058
43
380-480V, 3-Phase
60
CIMR-PU4A00881
80
200
05P00620-0058
43
75
CIMR-PU4A01031
100
150
URX000204
47
380-480V, 3-Phase
100
CIMR-PU4A01391
130
100
05P00620-0066
47
125
CIMR-PU4A01651
160
75
URX000206
59
380-480V, 3-Phase
150
CIMR-PU4A02081
200
55
05P00620-0077
56
200
CIMR-PU4A02501
250
45
URX000248
65
380-480V, 3-Phase
250
CIMR-PU4A02961
320
40
URX000249
107
300
CIMR-PU4A03621
400
30
URX000250
111
380-480V, 3-Phase
350
CIMR-PU4A04141
500
25
URX000251
120
400
CIMR-PU4A05151
500
25
URX000251
120
380-480V, 3-Phase
450
CIMR-PU4A06751
600
20
URX000252
264
500
CIMR-PU4A06751
600
20
URX000252
264
380-480V, 3-Phase
600
CIMR-PU4A06751
750
15
URX000253
299
660
CIMR-PU4A09301
750
15
URX000253
299
380-480V, 3-Phase
700
CIMR-PU4A09301
900
13
URX000254
444
750
CIMR-PU4A09301
900
13
URX000254
444
380-480V, 3-Phase
800
CIMR-PU4A12001
1000
11
URX000244
479
900
CIMR-PU4A12001
1200
9
URX000246
584
380-480V, 3-Phase
1000
CIMR-PU4A12001
1200
9
URX000246
584
1"Large" P1000 chassis have a built-in DC link reactor equivalent to 3% line reactance. 240 VAC ratings are shown with 3% added AC reactance for 6% total.

Top

380-480V, 5% Line/Load Reactors
Rated Input Voltage
Nominal HP
Drive Model Number
Nominal 5% Impedance
Reactor Rated Current (A)
Inductance (μH)
Enclosed Part Number
Weight (lb)
380-480V, 3-Phase
1/2
CIMR-PU4A0002
1
36000
URX000241
11
3/4
CIMR-PU4A0002
2
20000
05P00620-0016
11
380-480V, 3-Phase
1
CIMR-PU4A0002
2
20000
05P00620-0016
11
1.5
CIMR-PU4A0004
4
12000
05P00620-0023
13
380-480V, 3-Phase
2
CIMR-PU4A0004
4
12000
05P00620-0023
13
3
CIMR-PU4A0005
8
7500
URX000226
20
380-480V, 3-Phase
5
CIMR-PU4A0009
8
5000
05P00620-0029
18
7.5
CIMR-PU4A0011
12
4200
05P00620-0034
25
380-480V, 3-Phase
10
CIMR-PU4A0018
18
2500
05P00620-0038
34
15
CIMR-PU4A0023
25
1800
05P00620-0043
38
380-480V, 3-Phase
20
CIMR-PU4A0031
35
1200
05P00620-0048
48
25
CIMR-PU4A0038
35
1200
05P00620-0048
48
380-480V, 3-Phase
30
CIMR-PU4A0044
45
1200
05P00620-0052
57
380-480V, 3-Phase
40
CIMR-PU4A00581
55
500
05P00620-0055
45
50
CIMR-PU4A00721
80
400
05P00620-0059
51
380-480V, 3-Phase
60
CIMR-PU4A00881
80
400
05P00620-0059
51
75
CIMR-PU4A01031
100
300
05P00620-0062
55
380-480V, 3-Phase
100
CIMR-PU4A01391
130
200
05P00620-0067
61
125
CIMR-PU4A01651
160
150
05P00620-0073
68
380-480V, 3-Phase
150
CIMR-PU4A02081
200
110
05P00620-0078
72
200
CIMR-PU4A02501
250
90
05P00620-0083
107
380-480V, 3-Phase
250
CIMR-PU4A02961
320
75
05P00620-0088
129
300
CIMR-PU4A03621
400
60
05P00620-0092
145
380-480V, 3-Phase
350
CIMR-PU4A04141
500
50
05P00620-0096
262
400
CIMR-PU4A05151
500
50
05P00620-0096
262
380-480V, 3-Phase
450
CIMR-PU4A06751
600
40
05P00620-0100
319
500
CIMR-PU4A06751
600
40
05P00620-0100
319
380-480V, 3-Phase
600
CIMR-PU4A06751
750
29
05P00620-0104
349
660
CIMR-PU4A09301
750
29
05P00620-0104
349
380-480V, 3-Phase
700
CIMR-PU4A09301
900
25
URX000255
529
750
CIMR-PU4A09301
900
25
URX000255
529
380-480V, 3-Phase
800
CIMR-PU4A12001
1000
22
URX000245
567
900
CIMR-PU4A12001
1200
19
URX000247
599
380-480V, 3-Phase
1000
CIMR-PU4A12001
1200
19
URX000247
599
1"Large" P1000 chassis have a built-in DC link reactor equivalent to 3% line reactance. 240 VAC ratings are shown with 3% added AC reactance for 6% total.

Top

480V, Single- Phase Line/Load Reactors
Rated Input Voltage
Nominal HP
Drive Model Number
Enclosed AC Reactor
Current (A)
Inductance (μH)
Part Number
480V, 1-Phase
1/2
CIMR-PU4A0002
3.4
3.200
URX000409
1
CIMR-PU4A0004
4.8
2.300
URX000410
480V, 1-Phase
1.5
CIMR-PU4A0005
6
1.500
URX000411
2
CIMR-PU4A0007
11
2.100
URX000414
480V, 1-Phase
3
CIMR-PU4A0009
14
1.600
URX000416
3
CIMR-PU4A0011
21
1.100
URX000419
480V, 1-Phase
3
CIMR-PU4A0018
21
1.100
URX000419
5
CIMR-PU4A0023
21
1.100
URX000419
480V, 1-Phase
7.5
CIMR-PU4A0031
35
0.710
URX000423
10
CIMR-PU4A0038
46
0.550
URX000425
480V, 1-Phase
10
CIMR-PU4A0044
46
0.550
URX000425
15
CIMR-PU4A0058
65
0.190
URX000426
480V, 1-Phase
15
CIMR-PU4A0072
Do Not Use AC Reactor
480V, 1-Phase
15
CIMR-PU4A0088
20
CIMR-PU4A0103
83
0.170
URX000427
480V, 1-Phase
30
CIMR-PU4A0139
130
0.950
URX000429
30
CIMR-PU4A0165
130
0.950
URX000429
480V, 1-Phase
50
CIMR-PU4A0208
200
0.600
URX000431
60
CIMR-PU4A0250
200
0.600
URX000431
480V, 1-Phase
75
CIMR-PU4A0296
250
0.500
URX000432
100
CIMR-PU4A0362
322
0.050
URX000433
480V, 1-Phase
125
CIMR-PU4A0414
414
0.033
URX000434
100
CIMR-PU4A0515
322
0.050
URX000433
480V, 1-Phase
125
CIMR-PU4A0675
Do Not Use AC Reactor

Top

500-600V, 3% Line/Load Reactors
Rated Input Voltage
Nominal HP
Drive Model Number
Nominal 3% Impedance
Reactor Rated Current (A)
Inductance (μH)
Enclosed Part Number
Weight (lb)
500-600V, 3-Phase
1/2
CIMR-PU5A0003
1
36000
URX000241
11
3/4
CIMR-PU5A0003
2
20000
05P00620-0016
11
500-600V, 3-Phase
1
CIMR-PU5A0003
2
20000
05P00620-0016
11
1.5
CIMR-PU5A0003
2
20000
05P00620-0016
11
500-600V, 3-Phase
2
CIMR-PU5A0003
4
9000
05P00620-0022
12
3
CIMR-PU5A0004
4
9000
05P00620-0022
12
500-600V, 3-Phase
5
CIMR-PU5A0006
8
5000
05P00620-0029
18
7.5
CIMR-PU5A0009
12
2500
05P00620-0033
17
500-600V, 3-Phase
10
CIMR-PU5A0011
12
2500
05P00620-0033
17
15
CIMR-PU5A0017
18
1500
05P00620-0037
19
500-600V, 3-Phase
20
CIMR-PU5A0022
25
1200
05P00620-0042
32
25
CIMR-PU5A0027
25
1200
05P00620-0042
32
500-600V, 3-Phase
30
CIMR-PU5A0032
35
800
05P00620-0047
34
500-600V, 3-Phase
40
CIMR-PU5A00411
45
300
05P00620-0050
41
50
CIMR-PU5A00521
55
250
05P00620-0054
42
500-600V, 3-Phase
60
CIMR-PU5A00621
80
200
05P00620-0058
43
75
CIMR-PU5A00771
80
200
05P00620-0058
43
500-600V, 3-Phase
100
CIMR-PU5A00991
100
150
URX000204
47
125
CIMR-PU5A01251
130
100
05P00620-0066
47
500-600V, 3-Phase
150
CIMR-PU5A01451
160
75
URX000206
59
200
CIMR-PU5A01921
200
55
05P00620-0077
56
500-600V, 3-Phase
250
CIMR-PU5A02421
250
45
05P00620-0077
65
1"Large" P1000 chassis have a built-in DC link reactor equivalent to 3% line reactance. 240 VAC ratings are shown with 3% added AC reactance for 6% total.

Top

500-600V, 5% Line/Load Reactors
Rated Input Voltage
Nominal HP
Drive Model Number
Nominal 5% Impedance
Reactor Rated Current (A)
Inductance (μH)
Enclosed Part Number
Weight (lb)
500-600V, 3-Phase
1/2
CIMR-PU5A0003
1
18000
URX000242
11
3/4
CIMR-PU5A0003
2
32000
URX000227
11
500-600V, 3-Phase
1
CIMR-PU5A0003
2
32000
URX000227
11
1.5
CIMR-PU5A0003
2
32000
URX000227
11
500-600V, 3-Phase
2
CIMR-PU5A0003
4
12000
05P00620-0023
13
3
CIMR-PU5A0004
4
12000
05P00620-0023
13
500-600V, 3-Phase
5
CIMR-PU5A0006
8
7500
URX000226
20
7.5
CIMR-PU5A0009
12
4200
05P00620-0034
25
500-600V, 3-Phase
10
CIMR-PU5A0011
12
4200
05P00620-0034
25
15
CIMR-PU5A0017
18
2500
05P00620-0038
34
500-600V, 3-Phase
20
CIMR-PU5A0022
25
1800
05P00620-0043
38
25
CIMR-PU5A0027
25
1800
05P00620-0043
38
500-600V, 3-Phase
30
CIMR-PU5A0032
35
1200
05P00620-0048
48
500-600V, 3-Phase
40
CIMR-PU5A00411
45
700
05P00620-0051
46
50
CIMR-PU5A00521
55
500
05P00620-0055
45
500-600V, 3-Phase
60
CIMR-PU5A00621
80
400
05P00620-0059
51
75
CIMR-PU5A00771
80
400
05P00620-0059
51
500-600V, 3-Phase
100
CIMR-PU5A00991
100
300
05P00620-0062
55
125
CIMR-PU5A01251
130
200
05P00620-0067
61
500-600V, 3-Phase
150
CIMR-PU5A01451
160
150
05P00620-0073
68
200
CIMR-PU5A01921
200
110
05P00620-0078
72
500-600V, 3-Phase
250
CIMR-PU5A02421
250
90
05P00620-0083
107
1"Large" P1000 chassis have a built-in DC link reactor equivalent to 3% line reactance. 240 VAC ratings are shown with 3% added AC reactance for 6% total.

Top

600V, Single-Phase Line/Load Reactors
Rated Input Voltage
Nominal HP
Drive Model Number
Enclosed DC Reactor
Current (A)
Inductance (μH)
Part Number
600V, 1-Phase
1.5
CIMR-PU5A0003
6
1.500
URX000411
2
CIMR-PU5A0004
7.6
6.000
URX000411
600V, 1-Phase
3
CIMR-PU5A0006
11
2.100
URX000414
5
CIMR-PU5A0009
14
2.600
URX000417
600V, 1-Phase
3
CIMR-PU5A0011
11
2.100
URX000414
5
CIMR-PU5A0017
21
1.100
URX000419
600V, 1-Phase
7.5
CIMR-PU5A0022
28
0.820
URX000421
10
CIMR-PU5A0027
35
0.710
URX000423
600V, 1-Phase
10
CIMR-PU5A0032
35
0.710
URX000423
15
CIMR-PU5A0041
46
0.300
URX000424
600V, 1-Phase
15
CIMR-PU5A0052
46
0.300
URX000424
25
CIMR-PU5A0062
83
0.170
URX000427
600V, 1-Phase
30
CIMR-PU5A0077
104
0.120
URX000428
600V, 1-Phase
30
CIMR-PU5A0099
104
0.120
URX000428
50
CIMR-PU5A0125
160
0.080
URX000430
600V, 1-Phase
50
CIMR-PU5A0145
160
0.080
URX000430
75
CIMR-PU5A0192
200
0.600
URX000431
600V, 1-Phase
75
CIMR-PU5A0242
200
0.600
URX000431