;============================================================================= ; ; (c) 1999 Yaskawa Electric Corp. ; ; Device Database file for I/O type Profibus-DP Interface ; JUSP-NS500 for Sigma-II series Servopacks ; ; File Name: YASK0508.GSD ; Author: Friedrich Esselborn ; Creation Date: 1999-12-21 ; Changes: ; 2000-01-09 MODEL_NAME ; Hardware_Release ; Software_Release ; Repeater_Ctrl_Sig ; 2000-01-10 Bitmap comment ; User_Prm_Data_Len: removed entry ; ;============================================================================= ; ;--- General Information: --- ; #Profibus_DP GSD_Revision = 2 ; Vendor_Name = "Yaskawa Electric Corporation" Model_Name = "JUSP-NS500" Revision = "V1.0" Ident_Number = 0x0508 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "V00" Software_Release = "V001" ; 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 ; MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 ; Redundancy = 0 Repeater_Ctrl_Sig = 0 ; 0: Not connected, 1: RS485, 2: TTL 24V_Pins = 0 ; 0: Not connected, 1: Input, 2: Output Implementation_Type = "SPC 3" ;TODO: provide bitmap files for device representation ;Bitmap_Device = "Bitmap1N" ;Bitmap_Diag = "Bitmap1D" ;Bitmap_SF = "Bitmap1S" ; ;--- Slave specific Values --- ; Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 5 ; Modular_Station = 0 Modul_Offset = 0 Max_User_Prm_Data_Len= 0 ; Fail_Safe = 1 Slave_Family = 1 Max_Diag_Data_Len = 6 ; Module = "NS500: 8 Byte Out, 8 Byte In" 0xA7, 0x97 EndModule ;