iQpump 7 Series

Models & Ratings (Standard)

Pump Controllers - 5-500HP, 208-230/240 and 480V, 3-phase1 input, NEMA 1 or protected chassis enclosure

208V | 240V | 230V | 480V

208V

Catalog Model Number
Drive Model Number
Rated Output
Current (Amps)
Nominal HP2
Standard Enclosure
CIMR-P7U23P71-107
CIMR-P7U23P71A-107
16.8
5
NEMA 1
CIMR-P7U25P51-107
CIMR-P7U25P51A-107
23.0
53
NEMA 1
CIMR-P7U27P51-107
CIMR-P7U27P51A-107
31.0
7.5
NEMA 1
CIMR-P7U27P51-107
CIMR-P7U27P51A-107
31.0
10
NEMA 1
CIMR-P7U20111-107
CIMR-P7U20111A-107
46.2
15
NEMA 1
CIMR-P7U20151-107
CIMR-P7U20151A-107
59.4
20
NEMA 1
CIMR-P7U20181-107
CIMR-P7U20181A-107
74.8
25
NEMA 1
CIMR-P7U20221-107
CIMR-P7U20221A-107
88
30
NEMA 1
CIMR-P7U20301-107
CIMR-P7U20301A-107
115
40
NEMA 1
CIMR-P7U20370-107
CIMR-P7U20370A-107
162
50
Protected Chassis
CIMR-P7U20450-107
CIMR-P7U20450A-107
192
60
Protected Chassis
CIMR-P7U20550-107
CIMR-P7U20550A-107
215
75
Protected Chassis
CIMR-P7U20750-107
CIMR-P7U20750A-107
312
100
Protected Chassis
CIMR-P7U20900-107
CIMR-P7U20900A-107
360
125
Protected Chassis
CIMR-P7U21100-107
CIMR-P7U21100A-107
415
150
Protected Chassis


Top

240V

Catalog Model Number
Drive Model Number
Rated Output
Current (Amps)
Nominal HP2
Standard Enclosure
CIMR-P7U23P71-107
CIMR-P7U23P71A-107
16.8
5
NEMA 1
CIMR-P7U25P51-107
CIMR-P7U25P51A-107
23.0
7.5
NEMA 1
CIMR-P7U27P51-107
CIMR-P7U27P51A-107
31.0
10
NEMA 1
CIMR-P7U20111-107
CIMR-P7U20111A-107
46.2
15
NEMA 1
CIMR-P7U20151-107
CIMR-P7U20151A-107
59.4
20
NEMA 1
CIMR-P7U20181-107
CIMR-P7U20181A-107
74.8
25
NEMA 1
CIMR-P7U20221-107
CIMR-P7U20221A-107
88
30
NEMA 1
CIMR-P7U20301-107
CIMR-P7U20301A-107
115
40
NEMA 1


Top

230V

Catalog Model Number
Drive Model Number
Rated Output
Current (Amps)
Nominal HP2
Standard Enclosure
CIMR-P7U20370-107
CIMR-P7U20370A-107
162
50
Protected Chassis
CIMR-P7U20370-107
CIMR-P7U20370A-107
162
60
Protected Chassis
CIMR-P7U20450-107
CIMR-P7U20450A-107
192
75
Protected Chassis
CIMR-P7U20550-107
CIMR-P7U20550A-107
215
753
Protected Chassis
CIMR-P7U20750-107
CIMR-P7U20750A-107
312
100
Protected Chassis
CIMR-P7U20750-107
CIMR-P7U20750A-107
312
125
Protected Chassis
CIMR-P7U20900-107
CIMR-P7U20900A-107
360
150
Protected Chassis
CIMR-P7U21100-107
CIMR-P7U21100A-107
415
1503
Protected Chassis


Top

480V

Catalog Model Number
Drive Model Number
Rated Output
Current (Amps)
Nominal HP2
Standard Enclosure
CIMR-P7U43P71-107
CIMR-P7U43P71A-107
7.6
5
NEMA 1
CIMR-P7U44P01-107
CIMR-P7U44P01A-107
8.7
53
NEMA 1
CIMR-P7U45P51-107
CIMR-P7U45P51A-107
12.5
7.5
NEMA 1
CIMR-P7U47P51-107
CIMR-P7U47P51A-107
17.0
10
NEMA 1
CIMR-P7U49P01-107
CIMR-P7U49P01A-107
21.0
15
NEMA 1
CIMR-P7U40111-107
CIMR-P7U40111A-107
27.0
20
NEMA 1
CIMR-P7U40151-107
CIMR-P7U40151A-107
34.0
25
NEMA 1
CIMR-P7U40181-107
CIMR-P7U40181A-107
40.0
30
NEMA 1
CIMR-P7U40221-107
CIMR-P7U40221A-107
50.4
303
NEMA 1
CIMR-P7U40241-107
CIMR-P7U40241A-107
52.0
40
NEMA 1
CIMR-P7U40301-107
CIMR-P7U40301A-107
67.2
50
NEMA 1
CIMR-P7U40371-107
CIMR-P7U40371A-107
77
60
NEMA 1
CIMR-P7U40451-107
CIMR-P7U40451A-107
96
75
NEMA 1
CIMR-P7U40551-107
CIMR-P7U40551A-107
125
100
NEMA 1
CIMR-P7U40750-107
CIMR-P7U40750A-107
156
125
Protected Chassis
CIMR-P7U40900-107
CIMR-P7U40900A-107
180
150
Protected Chassis
CIMR-P7U41100-107
CIMR-P7U41100A-107
240
200
Protected Chassis
CIMR-P7U41320-107
CIMR-P7U41320A-107
260
2003
Protected Chassis
CIMR-P7U41600-107
CIMR-P7U41600A-107
304
250
Protected Chassis
CIMR-P7U41850-107
CIMR-P7U41850A-107
414
300
Protected Chassis
CIMR-P7U41850-107
CIMR-P7U41850A-107
414
350
Protected Chassis
CIMR-P7U42200-107
CIMR-P7U42200A-107
515
400
Protected Chassis
CIMR-P7U42200-107
CIMR-P7U42200A-107
515
450
Protected Chassis
CIMR-P7U43000-107
CIMR-P7U43000A-107
675
500
Protected Chassis


Top

  1. Contact us at 800-YASKAWA (927-5292) for single phase applications and sizing.
  2. Horsepower rating is based on standard NEMA B 4-pole motor design as represented in NEC table 430.150 Full-Load Current, Three-Phase Alternating Current Motors