iQpump1000 Bypass

Specifications & Features

Performance Features

Bypass NEMA 3R and NEMA 12:

  • Ratings: 1 to 150 HP; 240VAC
  • 1 to 500 HP; 480VAC
     

Configured NEMA 3R: 12 Pulse Configured

  • Ratings: 50 to 500 HP, 480VAC
  • Max 8% harmonic distortion (THD) on input AC line
     

Service Conditions

  • Ambient service temperature:
    • NEMA 1 (IP20): -10°C to 40°C (14°F to 104°F)
    • NEMA 3R: -10°C to 40°C (14°F to 104°F)
    • NEMA 12: -10°C to 40°C (14°F to 104°F)
  • Ambient storage temperature -20°C to 70°C (-4°F to 158°F)
  • Humidity: 0% to 95%, non-condensing
  • Altitude: to 1000 meters (3300 feet); higher by derating
  • Vibration: 0.33 mm (10 to 20 Hz), 0.22 G (20 to 55 Hz)
     

Bypass Features

  • Output and bypass contactors
  • Circuit breaker disconnect (MCP), with interlocked, flange-mount operating mechanism
  • Input fuses
  • Thermal motor overload relay, class 20
  • 115 VAC control transformer, fused
  • Drive/Bypass selector switch
  • Hand/Off/Auto selector switch
  • Pilot lights, 22m LED, for Drive Run, Bypass Run and Fault
  • Run Mode, Auto mode and Fault contacts
  • Control and safety circuit terminal strip
     

Standard and Reliability

  • UL 508A (Industrial Control Panels)
  • UL, cUL listed
     

Configured Options

  • NEMA 1
    • Output cards
    • Network Communication cards
    • Input breaker 65k
    • Line/load reactors
    • Bus reactor (for small HP ratings, see tables)
    • Input filter
    • Door-mounted operator controls
       
  • NEMA 3R
    • Output cards
    • Network communication cards
    • Input breaker 65k
    • Line/load reactors
    • Bus reactor (for small HP ratings, see tables)
    • Input filter
    • Door-mounted operator controls
    • Door-mounted keypad viewing window
    • Conventional surge suppressor
    • High energy surge suppressor
    • Over voltage line disconnect
    • Space heater
    • 50°C ambient
       
  • NEMA 12
    • Output cards
    • Network communication cards
    • Input breaker 65k
    • Line/load reactors
    • Bus reactor (for small HP ratings, see tables)
    • Input filter
    • Door-mounted operator controls
       
  • NEMA 12-Pulse Configured
    • Output cards
    • Network communication cards
    • Input breaker (65k)
    • Input filter
    • Door-mounted operator controls
    • Door-mounted keypad viewing window
    • Conventional surge suppressor
    • High energy surge suppressor
    • Over voltage line disconnect
    • Space heater