CSA Certificate of Compliance for Z1000 Variable Speed Drives for AC Motors, Series CIMR, followed by Z, followed by A through Z, followed by 2, 4 or 5 followed by A through Z, followed by XXXX, where XXXX is 0005 through 0590, followed by A or F, followed by XX, where XX is AA through ZZ; open or enclosed type 1 drives; Ratings: Input: 200 to 240Vac, 10.6A to 396A, 50/60Hz; Output: 0-240Vac, 396A to 21A, 0/240Hz; Input: 380 to 480Vac, 4.8A to 590A, 50/60Hz; Output: 0-480Vac, 4.8A to 590A, 0/240Hz; Input: 500 to 600Vac, 3.6A to 263A, 50/60Hz; Output: 0-600Vac, 2.7A to 242A, 0/240Hz Short Circuit: 100 kA RMS, 480 Vac maximum. NOTE: This compliance document pertains to individual drives that may be used as part of a Bypass, Configured, or Engineered package within an enclosure. The document does not exclusively make any compliance claims regarding the enclosure in which they are housed.
2016 Report from the VMC Group: OSHPD Special Seismic Certification Preapproval (OSP) for Yaskawa A1000, and Z1000 VFDs & J1000, P1000, and V1000 Micro Drives. J1000 drive no longer available.
This document links directly to all UL Listed Yaskawa product pages on the UL website. Links are included within the attached PDF file.NOTE: This compliance document pertains to individual drives that may be used as part of a Bypass, Configured, or Engineered package within an enclosure. The document does not exclusively make any compliance claims regarding the enclosure in which they are housed, unless otherwise stipulated.
This is to certify that representative samples of POWER CONVERSION EQUIPMENT Drives, Model CIMR, followed by Z, followed by A through Z, followed by 2 or 4 followed by A through Z, followed by XXXX, where XXXX is 0005 through 0590, followed by A, F or U, followed by XX, where XX is AA through ZZ. Have been investigated by UL in accordance with the Standard(s) indicated below. Standard(s) for Safety: UL 508C, Power Conversion Equipment CSA C22.2 No. 14-10, Industrial Control Equipment See the UL Online Certifications Directory at www.ul.com/database for additional information Certificate Number 20130308-E131457 Report Reference E131457-20110309
Certificate of Compliance from VMC Group: SEISMIC DESIGN OF NON-STRUCTURAL COMPONENTS AND SYSTEMS for A1000 Drives, P1000 Drives, V1000 Drives, iQpump Micro Drives, Z1000 Drives, Z1000 Bypass, and Z1000 Configured
It looks like you are using Internet Explorer 11 or below, this website isn`t compatible with this and for the best experience please use the latest version of Mozilla Firefox, Google Chrome or Safari.