SGLF Series
Models & Ratings
Specification | Linear Servomotor Model Number | ||||||||
---|---|---|---|---|---|---|---|---|---|
SGLFW-20A1 | SGLFW-35A2 | SGLFW-50A3 | SGLFW-1ZA3 | ||||||
090A | 120A | 120A | 230A | 200A | 380A | 200A | 380A | ||
Continuous Output | W | 125 | 140 | 200 | 400 | 500 | 1000 | 1000 | 2000 |
Continuous Force | N | 25 | 40 | 80 | 160 | 200 | 400 | 400 | 800 |
Continuous Current | ARMS | 0.7 | 0.8 | 1.4 | 2.8 | 3.2 | 6.3 | 5.7 | 14.4 |
Peak Force | N | 86 | 125 | 220 | 440 | 600 | 1200 | 1200 | 2400 |
Peak Current | ARMS | 3.0 | 2.9 | 4.4 | 8.8 | 10.9 | 21.8 | 19.7 | 39.3 |
Moving Coil Mass | kg | 0.7 | 0.9 | 1.3 | 2.3 | 3.7 | 6.9 | 6.40 | 11.5 |
Force Constant | N/ARMS | 36.0 | 54.0 | 62.4 | 62.4 | 67.9 | 67.9 | 75.3 | 75.3 |
BEMF Constant | V/(m/s) | 12.0 | 18.0 | 20.8 | 20.8 | 22.6 | 22.6 | 25.1 | 25.1 |
Motor Constant | N/√W | 7.9 | 9.8 | 14.4 | 20.4 | 29.3 | 41.1 | 44.6 | 62.4 |
Electrical Time Constant | ms | 3.2 | 3.3 | 3.6 | 3.6 | 9.6 | 9.4 | 10.4 | 9.7 |
Mechanical Time Constant | ms | 11.1 | 9.3 | 6.2 | 5.5 | 4.1 | 4.1 | 3.2 | 3 |
Thermal Resistance (with Heatsink) | K/W | 4.35 | 3.19 | 1.57 | 0.96 | 1.12 | 0.46 | 0.82 | 0.39 |
Thermal Resistance (without Heatsink) | K/W | 7.69 | 5.02 | 4.1 | 1.94 | 2.13 | 1.06 | 1.34 | 0.79 |
Magnetic Attraction Force | N | 314 | 462 | 809 | 1586 | 2095 | 4144 | 4190 | 8289 |
Note: Values when the linear motor is combined with the SGDH Sigma II amplifier.
1These values are with aluminum heatsink (125x125x13mm) mounted to the motor coil.
2These values are with aluminum heatsink (254x254x25mm) mounted to the motor coil.
3These values are with aluminum heatsink (200A : 254x254x25mm, 380A : 400x500x40mm) mounted to the motor coil.
Node: lr2
|