D1000 Regenerative Converter

Specifications

Item
Specification
Load Rating 100% continuous power
Overload Capacity 150% for 30 second, 200% for 3 seconds
Output Voltage Regulation ± 5%
Protective Design Protected chassis (NEMA 1 kit available)
Ambient Operating Temperature -10 to +50°C (IP00)
-10 to +40°C (with NEMA 1 kit)
Certifications UL, CSA B44.1, CE, RoHS
Standard I/O (8) multi-function digital inputs (24Vdc)
(3) multi-function analog inputs (0 +/- 10 VDC, 4-20 mA)
(1) fault relay output (form C)
(3) multi-function relay outputs (form A)
(2) multi-function analog output (0 +/- 10 VDC, 4-20mA)
I/O Expansion 2 Analog Outputs (-10 to +10V, 11 bit magnitude)
8 Digital Outputs (6 transistor, 2 relay)
Network Communication Standard:
Modbus RTU, RS-422/485, 115 kbps

Optional:
EtherNet IP, DeviceNet, Modbus TCP/IP, PROFINET, PROFIBUS-DP