A1000 - DC Reactors

200-240V, 3-Phase | 380-480V, 3-Phase | 500-600V, 3-Phase

For Nominal HP and Rated Input Voltage, see Models & Ratings.

200-240, 3-Phase

Drive Model Number
Rated DC Current (A)
3% Enclosed Reactor
5% Enclosed Reactor
Normal Duty
Heavy Duty
Inductance (μH)
Reactor Part Number
Weight (lb)
Inductance (μH)
Reactor Part Number
Weight (lb)
CIMR-AU2A0004
CIMR-AU2A0004
2
10000
TBD
TBD
2
TBD
TBD
CIMR-AU2A0004
CIMR-AU2A0004
4
5000
TBD
TBD
4
URX000207
9
CIMR-AU2A0006
CIMR-AU2A0006
4
5000
TBD
TBD
4
URX000207
9
CIMR-AU2A0006
CIMR-AU2A0008
9
3220
URX000257
9
9
URX000208
11
CIMR-AU2A0008
CIMR-AU2A0008
9
3220
URX000257
9
9
URX000208
11
CIMR-AU2A0010
CIMR-AU2A0012
12
2100
URX000258
11
12
URX000209
11
CIMR-AU2A0018
CIMR-AU2A0021
18
1375
URX000259
11
18
URX000210
14
CIMR-AU2A0021
CIMR-AU2A0030
25
1000
TBD
TBD
25
URX000211
14
CIMR-AU2A0030
CIMR-AU2A0040
32
850
URX000261
12
32
URX000223
28
CIMR-AU2A0040
CIMR-AU2A0056
50
625
URX000262
15
50
TBD
TBD
CIMR-AU2A0056
CIMR-AU2A0069
62
320
URX000264
26
62
URX000213
32
CIMR-AU2A0069
CIMR-AU2A0081
80
310
TBD
TBD
80
TBD
TBD
CIMR-AU2A0081
CIMR-AU2A0110
92
200
URX000266
28
92
URX000265
41
Built-in

Top

 

380-480, 3-Phase

Drive Model Number
Rated DC Current (A)
3% Enclosed Reactor
5% Enclosed Reactor
Normal Duty
Heavy Duty
Inductance (μH)
Reactor Part Number
Weight (lb)
Inductance (μH)
Reactor Part Number
Weight (lb)
CIMR-AU4A0002
CIMR-AU4A0002
2
50000
URX000215
9
50000
URX000215
9
CIMR-AU4A0002
CIMR-AU4A0002
4
20000
TBD
TBD
50000
URX000215
9
CIMR-AU4A0002
CIMR-AU4A0004
4
20000
TBD
TBD
50000
URX000215
9
CIMR-AU4A0004
CIMR-AU4A0004
9
15000
URX000217
9
25000
URX000216
11
CIMR-AU4A0004
CIMR-AU4A0004
9
15000
URX000217
9
25000
URX000216
11
CIMR-AU4A0005
CIMR-AU4A0005
12
7500
URX000208
11
11500
URX000218
14
CIMR-AU4A0009
CIMR-AU4A0011
18
7500
URX000208
11
11500
URX000218
14
CIMR-AU4A0011
CIMR-AU4A0018
25
4000
URX000209
11
6000
URX000219
11
CIMR-AU4A0018
CIMR-AU4A0018
32
2750
URX000210
14
6000
URX000260
31
CIMR-AU4A0023
CIMR-AU4A0031
50
1750
URX000211
14
4000
URX000224
31
CIMR-AU4A0031
CIMR-AU4A0038
62
1620
URX000223
28
2680
URX000221
32
CIMR-AU4A0038
CIMR-AU4A0044
80
1000
URX000184
15
2500
URX000225
39
CIMR-AU4A0044
CIMR-AU4A0058
92
970
TBD
TBD
2000
URX000263
43
Built-in

Top

500-600, 3-Phase

Drive Model Number
Rated DC Current (A)
3% Enclosed Reactor
5% Enclosed Reactor
Normal Duty
Heavy Duty
Inductance (μH)
Reactor Part Number
Weight (lb)
Inductance (μH)
Reactor Part Number
Weight (lb)
CIMR-AU5A0003
CIMR-AU5A0003
1
60000
TBD
TBD
80000
TBD
TBD
CIMR-AU5A0003
CIMR-AU5A0003
2
50000
URX000215
9
50000
URX000215
9
CIMR-AU5A0003
CIMR-AU5A0003
2
20000
TBD
TBD
50000
URX000215
9
CIMR-AU5A0003
CIMR-AU5A0004
4
15000
URX000217
9
25000
URX000216
11
CIMR-AU5A0003
CIMR-AU5A0004
4
15000
URX000217
9
25000
URX000216
11
CIMR-AU5A0004
CIMR-AU5A0006
4
12000
URX000207
9
25000
URX000216
11
CIMR-AU5A0006
CIMR-AU5A0009
9
7500
URX000208
11
11500
URX000218
14
CIMR-AU5A0009
CIMR-AU5A0011
12
4000
URX000209
11
6000
URX000219
11
CIMR-AU5A0011
CIMR-AU5A0017
18
4000
URX000209
11
3750
URX000220
15
CIMR-AU5A0017
CIMR-AU5A0022
25
2750
URX000210
14
4000
URX000224
31
CIMR-AU5A0022
CIMR-AU5A0027
25
1750
URX000211
14
4000
URX000224
31
CIMR-AU5A0027
CIMR-AU5A0032
32
1620
URX000223
28
2680
URX000221
32
CIMR-AU5A0032
CIMR-AU5A0041
50
1000
URX000184
15
2000
URX000263
43
Built-in