R1000 Regenerative Unit

Specifications

Item
Specification
Load Rating
100% power, 25% duty cycle (60 second maximum on time), or 80% continuous
Overload Capacity
150% for 30 second
Protective Design
NEMA 1 Standard - Up to 28kW
IP00 - 35kW and above
(No NEMA 1 kits available)
Ambient Operating Temperature
-10 to +50°C (IP00)
-10 to +40°C (with NEMA 1 kit)
Certifications
UL, CSA B44.1, CE, RoHS
Standard I/O
(8) multi-function digital inputs (24Vdc)
(3) multi-function analog inputs (0 +/- 10 VDC, 4-20 mA)
(1) fault relay output (form C)
(3) multi-function relay outputs (form A)
(2) multi-function analog output (0 +/- 10 VDC, 4-20mA)
I/O Expansion
2 Analog Outputs (-10 to +10V, 11 bit magnitude)
8 Digital Outputs (6 transistor, 2 relay)
Network Communication
Standard: Modbus RTU, RS-422/485, 115 kbps
Optional: EtherNet IP, DeviceNet, Modbus TCP/IP, PROFINET, PROFIBUS-DP

Additional specifications can be found within the R1000 Instruction Manual (Doc# TOEPC71065608) under the Specifications section.