V1000 Drive
Breadcrumb
Navigation Menu
Products
V1000 Drive
V1000 Drive
V1000 Drive - YAIALL
1/8 - 25 HP
The V1000 is a world-class compact current vector drive that defines a new world standard. Demands for efficient production and better maintainability are on the rise, spurred by global competition. Yaskawa pays off the promise of being in control with products that make businesses move. The optimum balance of energy input, product output, maintenance risk, and long life is reached with Yaskawa. The V1000 provides a world of power in the palm of your hand!
The V1000 is the flagship drive of the V1000 Family, which also includes the V1000-4X.
TemplateWeb
Models & Ratings
V1000 Drive - Overview
200-240V 1-Phase | 200-240V 3-Phase | 380-480V 3-Phase
200-240V, 1-Phase
Drive Model Number | Normal Duty1 | Heavy Duty1 | Standard Enclosure | ||
---|---|---|---|---|---|
Rated Output Current (Amps) |
Nominal HP2 | Rated Output Current (Amps) |
Nominal HP2 | ||
CIMR-VUBA0001FAA | 1.2 | 1/8 & 1/4 | 0.8 | 1/8 | NEMA 1 |
CIMR-VUBA0002FAA | 1.9 | 1/4 | 1.6 | 1/4 | |
CIMR-VUBA0003FAA | 3.3 | 1/2 & 3/4 | 3.0 | 1/2 | NEMA 1 |
CIMR-VUBA0006FAA | 6.0 | 1 | 5.0 | 3/4 & 1 | |
CIMR-VUBA0010FAA | 9.6 | 2 & 3 | 8.0 | 2 | NEMA 1 |
CIMR-VUBA0012FAA | 12.0 | 3 | 11.0 | 3 | |
CIMR-VUBA0018FAA | 17.5 | 5 | 17.5 | 5 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
200-240V, 3-Phase
Drive Model Number | Normal Duty1 | Heavy Duty1 | Standard Enclosure | ||
---|---|---|---|---|---|
Rated Output Current (Amps) |
Nominal HP2 | Rated Output Current (Amps) |
Nominal HP2 | ||
CIMR-VU2A0001FAA | 1.2 | 1/8 & 1/4 | 0.8 | 1/8 | NEMA 1 |
CIMR-VU2A0002FAA | 1.9 | 1/4 | 1.6 | 1/4 | |
CIMR-VU2A0004FAA | 3.5 | 1/2 & 3/4 | 3.0 | 1/2 | |
CIMR-VU2A0006FAA | 6.0 | 1 | 5.0 | 3/4 & 1 | NEMA 1 |
CIMR-VU2A0010FAA | 9.6 | 2 & 3 | 8.0 | 2 | |
CIMR-VU2A0012FAA | 12 | 3 | 11.0 | 3 | |
CIMR-VU2A0020FAA | 19.6 | 5 | 17.5 | 5 | NEMA 1 |
CIMR-VU2A0030FAA | 30 | 7.5 & 10 | 25 | 7.5 | |
CIMR-VU2A0040FAA | 40 | 10 | 33 | 10 | |
CIMR-VU2A0056FAA | 56 | 20 | 47 | 15 | NEMA 1 |
CIMR-VU2A0069FAA | 69 | 25 | 60 | 20 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.
380-480V 3-Phase
Drive Model Number | Normal Duty1 | Heavy Duty1 | Standard Enclosure | ||
---|---|---|---|---|---|
Rated Output Current (Amps) |
Nominal HP2 | Rated Output Current (Amps) |
Nominal HP2 | ||
CIMR-VU4A0001FAA | 1.2 | 1/2 | 1.2 | 1/2 | NEMA 1 |
CIMR-VU4A0002FAA | 2.1 | 3/4 & 1 | 1.8 | 3/4 | |
CIMR-VU4A0004FAA | 4.1 | 2 | 3.4 | 1 & 2 | NEMA 1 |
CIMR-VU4A0005FAA | 5.4 | 3 | 4.8 | 3 | |
CIMR-VU4A0007FAA | 6.9 | 4 | 5.5 | 3 | NEMA 1 |
CIMR-VU4A0009FAA | 8.8 | 5 | 7.2 | 4 | |
CIMR-VU4A0011FAA | 11.1 | 7.5 | 9.2 | 5 | NEMA 1 |
CIMR-VU4A0018FAA | 17.5 | 10 | 14.8 | 7.5 & 10 | |
CIMR-VU4A0023FAA | 23 | 15 | 18 | 10 | NEMA 1 |
CIMR-VU4A0031FAA | 31 | 20 | 24 | 15 | |
CIMR-VU4A0038FAA | 38 | 25 | 31 | 20 |
- Normal Duty overload current rating is 120% of rated output current for 60 seconds; Heavy Duty overload current rating is 150% of rated output current for 60 seconds
- Horsepower rating is based on 230 Volt and 460 Volt Induction-Type Squirrel Cage NEMA B 4-Pole Motors as represented in NEC Table 430.250 Full-Load Current, Three-Phase Alternating-Current Motors.