NS500 Profibus

Specifications

 

Position Loop Update 250 usec
Dedicated Digital Inputs (6) 24 VDC optically isolated
Estop, Extp (Latch), Dec (home near), Zero (home), P-OT, N-OT (overtravel limit switch)
Dedicated Digital Outputs (9) 24VDC optically isolated
ALM (alarm out), S-RDY (servo-ready), BK (holding brake), COIN (in-position), 3 alarm codes, and 2 NOTCH (output based on position)
ALM, S-RDY, BK reconfigurable to five other functions
Auxiliary encoder Input (1) encoder input, 1 Mhz, A,B,C channel, Full closed loop (Position loop uses external encoder at load)
Encoder Output Scalable encoder position output
Serial Port (1) RS232 for setup only
DeviceNet Communication (1) Profibus DP port, 9.6 kbps to 12 MHz, Autobaud detects master baud rate
Profibus Conformance Profibus DP conformance tested
Motion Functions Four types of homing
Eight types of acceleration/deceleration
Separate setting for acceleration and deceleration
S-curve acceleration
Jogging (feeding)
Point-to-point positioning
Point table positioning (50 speed/position points)
Multispeed positioning
Registration positioning
Full closed loop (auxiliary encoder attached to load)
 
Global Safety Certifications UL, CUL, CE
Dimensions (w,h,d) 0.79 x 5.59 x 5.04 inches (20 x 142 x 128) mm
Weight 0.44 lbs (0.2 kg)
Vibration 4.9 m/s^2
Ambient Temperature 0-45° C (32-113° F)
Humidity Less than 90%, non-condensing
Power Supplied from the SGDH amplifier